CD2-Z264-1
Circuit Breakers
CIRCUIT BREAKER
CD2-Z264-1
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Center To Center Distance Between Terminals Parallel To Length
3.537 inches minimum and 3.557 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.740 inches minimum and 2.760 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.016 inches minimum and 1.036 inches maximum
-
Fragility Factor
moderately rugged
-
Mounting Surface To Terminal End Distance
3.475 inches minimum and 3.495 inches maximum
-
Arc Quenching Method
magnetic blowout
-
Mounting Facility Type And Quantity
4 threaded hole
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
120.0 amperes dc second location
-
Maximum Continuous Load Current Rating Per Pole
150.0 milliamperes dc first location
-
Operating Voltage Type And Rating Per Pole In Volts
28.0 dc second location
-
Body Style
8c multipole-multiple actuator type
-
Body Length
4.740 inches minimum and 4.760 inches maximum
-
Body Width
2.072 inches maximum
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Width
1.016 inches minimum and 1.036 inches maximum
-
Boss Height
0.209 inches minimum and 0.229 inches maximum
-
Pole Quantity
2
-
Storage Type
general purpose warehouse
-
Features Provided
high inrush protection
-
Operating Voltage Type And Rating Per Pole In Volts
18.0 dc first location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 dc all locations
-
Circuit Protection Type
overcurrent all locations
-
Trip Release Method
magnetic all locations
-
Trip Release Characteristic
instantaneous first location
-
Trip Release Characteristic
time delay second location
-
Actuator Position Designation
at each pole
-
External Actuator Linkage Arrangement
one and two linked
-
Internal Trip Release Configuration
series trip all locations
-
Nominal Thread Size
0.138 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct and 13.000 maximum at 200 pct second location
-
Thread Series Designator
unc
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
2 toggle
-
Actuator Function
trip-reset
-
Inclosure Protection Type For Which Designed
vibrationproof and moisture resistant and shock resistant and salt spray proof
-
Terminal Type And Quantity
4 threaded stud