D1T-M80

Switches

SWITCH,PRESSURE

D1T-M80

5930-01-322-1081

5930 - Switches

Barksdale Inc

SWITCH,PRESSURE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Pressure Connector Type

    plain, threaded internal single connection

  • Mounting Facility Pattern

    two position in-line

  • Distance Between Mounting Facility Centers

    2.250 inches nominal

  • Inside Diameter

    0.495 inches nominal single connection

  • Pressure Switch Type

    gage

  • Body Height

    2.187 inches nominal

  • Contact Load Current Rating

    10.0 amperes resistive load first voltage

  • Contact Adjustment Range

    +3.30/+80.00 actuation point pounds per square inch and +0.50/+77.20 deactuation point pounds per square inch

  • Frequency In Hertz

    60.0 first voltage

  • Frequency In Hertz

    60.0 third voltage

  • Contact Voltage Rating In Volts

    125.0 ac at sea level first voltage

  • Media For Which Designed

    gas or liquid

  • Proof Pressure

    160.00 pounds per square inch

  • Terminal Type

    screw

  • Frequency In Hertz

    60.0 second voltage

  • Unthreaded Mounting Hole Diameter

    0.203 inches nominal

  • Contact Voltage Rating In Volts

    250.0 ac at sea level second voltage

  • Nonpile-Up Contact Arrangement

    1 pole, double throw, both positions maintained

  • End Item Identification

    air supply system onboard 400 ft wagb c.g. vessels

  • Overall Length

    4.562 inches nominal

  • Contact Adjustment Type

    external actuation point screw and external deactuation point screw

  • Overall Height

    4.343 inches nominal

  • Contact Load Current Rating

    10.0 amperes resistive load second voltage

  • Style Designator

    rectangular w/bracket

  • Contact Adjustability

    actuation point adjustable and deactuation point adjustable

  • Contact Voltage Rating In Volts

    480.0 ac at sea level third voltage

  • Features Provided

    electrical access port and internally grounded

  • Contact Load Current Rating

    3.0 amperes resistive load third voltage

  • Mounting Method

    bracket and unthreaded hole

  • Contact Action Stimulus

    increase

  • Overall Width

    3.483 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.