414-00005-08

Circuit Breakers

CIRCUIT BREAKER

414-00005-08

5925-01-322-2046

5925 - Circuit Breakers

Oeco Llc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Auxiliary Trip Coil Voltage Type And Rating In Volts

    25.0 dc nominal all locations

  • Nominal Thread Size

    0.134 inches

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac second location

  • Internal Trip Release Configuration

    series/relay trip all locations

  • Specification/Standard Data

    95266-414-00005-08 manufacturers source control

  • Body Length

    2.500 inches maximum

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc first location

  • Reset Method

    manual

  • Actuator Position Designation

    at each pole

  • Thread Series Designator

    unc

  • Pole Quantity

    2

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Continuous Load Current Rating Per Pole

    35.0 amperes dc first location

  • Fragility Factor

    moderately rugged

  • External Actuator Linkage Arrangement

    one and two linked

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.180 minimum at 200 pct second location and 1.800 maximum at 200 pct second location

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.745 inches minimum and 0.755 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.920 inches minimum and 1.960 inches maximum

  • Inclosure Protection Type For Which Designed

    moisture resistant and shock resistant and vibration resistant and salt spray proof

  • Thread Pitch Diameters

    +0.1177/+0.1214 inches

  • Body Width

    1.515 inches maximum

  • Manual Actuator Type And Quantity

    2 toggle

  • Trip Release Duty Cycle

    continuous all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.745 inches minimum and 0.755 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.700 minimum at 200 pct first location and 10.000 maximum at 200 pct first location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Surface To Terminal End Distance

    2.444 inches minimum and 2.506 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    65.0 dc first location

  • Terminal Type And Quantity

    8 threaded stud

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac second location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac second location

  • Frequency In Hertz

    60.0 second location

  • Body Style

    multipole-multiple actuator type

  • Trip Release Method

    magnetic all locations

  • Boss Height

    0.135 inches minimum and 0.165 inches maximum

  • Thread Quantity Per Inch

    32

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Mounting Facility Type And Quantity

    4 threaded hole

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...