414-00005-08
Circuit Breakers
CIRCUIT BREAKER
414-00005-08
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Auxiliary Trip Coil Voltage Type And Rating In Volts
25.0 dc nominal all locations
-
Nominal Thread Size
0.134 inches
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac second location
-
Internal Trip Release Configuration
series/relay trip all locations
-
Specification/Standard Data
95266-414-00005-08 manufacturers source control
-
Body Length
2.500 inches maximum
-
Actuator Function
trip-reset
-
Trip Release Characteristic
time delay all locations
-
Storage Type
general purpose warehouse
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc first location
-
Reset Method
manual
-
Actuator Position Designation
at each pole
-
Thread Series Designator
unc
-
Pole Quantity
2
-
Circuit Protection Type
overcurrent all locations
-
Maximum Continuous Load Current Rating Per Pole
35.0 amperes dc first location
-
Fragility Factor
moderately rugged
-
External Actuator Linkage Arrangement
one and two linked
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.180 minimum at 200 pct second location and 1.800 maximum at 200 pct second location
-
Case Material
plastic
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.745 inches minimum and 0.755 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
1.920 inches minimum and 1.960 inches maximum
-
Inclosure Protection Type For Which Designed
moisture resistant and shock resistant and vibration resistant and salt spray proof
-
Thread Pitch Diameters
+0.1177/+0.1214 inches
-
Body Width
1.515 inches maximum
-
Manual Actuator Type And Quantity
2 toggle
-
Trip Release Duty Cycle
continuous all locations
-
Center To Center Distance Between Terminals Parallel To Width
0.745 inches minimum and 0.755 inches maximum
-
Arc Quenching Method
magnetic blowout
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.700 minimum at 200 pct first location and 10.000 maximum at 200 pct first location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
-
Main Contact Tripping Mechanism Type
trip free
-
Mounting Surface To Terminal End Distance
2.444 inches minimum and 2.506 inches maximum
-
Operating Voltage Type And Rating Per Pole In Volts
65.0 dc first location
-
Terminal Type And Quantity
8 threaded stud
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac second location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac second location
-
Frequency In Hertz
60.0 second location
-
Body Style
multipole-multiple actuator type
-
Trip Release Method
magnetic all locations
-
Boss Height
0.135 inches minimum and 0.165 inches maximum
-
Thread Quantity Per Inch
32
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.050 inches minimum and 2.070 inches maximum
-
Mounting Facility Type And Quantity
4 threaded hole