11-00056-001
Coils and Transformers
COIL,RADIO FREQUENCY
11-00056-001
COIL,RADIO FREQUENCY
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Quantity
1 single group
-
Test Data Document
16340-11-00056 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Winding Operating Current
500.0 milliamperes maximum of standard range b single component single winding
-
Rating Method
electrical single component single winding
-
Coil Form Type
solid single component
-
Reliability Indicator
not established
-
Terminal Type And Quantity
2 wire lead
-
End Item Identification
5805-01-188-3993 central office,telephone,automatic
-
Maximum Operating Temp
125.0 deg celsius
-
Mounting Hole Diameter
0.218 inches minimum single group
-
Mounting Method
unthreaded hole single group
-
Dc Resistance Rating In Ohms
6.000 single component single winding
-
Inclosure Type
fully inclosed
-
Overall Diameter
1.050 inches maximum
-
Body Length
0.500 inches maximum
-
Inductance Rating
4.12 millihenries minimum single component single winding and 6.18 millihenries maximum single component single winding
-
Winding Conductor Size
0.02535 inches american wire gage single component single winding
-
Frequency At Which Inductance And Quality Factor Applies (Non-Core)
100.0 kilohertz single component single winding
-
Hazardous Locations/Environmental Protection
fungus resistant and corrosion resistant and vibration resistant
-
Core Construction
s0lid single component