726902-1
Coils and Transformers
TRANSFORMER,POWER
726902-1
General Dynamics Ots Aerospace Inc.
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Operating Voltage
42.42 ac volts nominal single component single primary
-
Winding Operating Voltage
84.84 ac volts nominal single component single secondary
-
Terminal Type And Quantity
4 wire lead
-
Overall Height
0.872 inches minimum and 0.892 inches maximum
-
Distance Between Mounting Facility Centers
1.103 inches minimum single mounting facility single center group and 1.123 inches maximum single mounting facility single center group
-
Body Length
0.890 inches minimum and 0.910 inches maximum
-
Winding Operating Current
3.0 amperes ac maximum single component single primary
-
Winding Power Rating
127.26 volts-amperes single component single primary
-
Mounting Method
tab single group
-
Mounting Tab Width
0.007 inches minimum and 0.027 inches maximum
-
Inclosure Type
fully inclosed
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Features Provided
color coded lead
-
Reliability Indicator
not established
-
Frequency Rating
30.0 kilohertz nominal single component
-
Input-Output Phase Relationship
single phase to single phase single component
-
Maximum Operating Temp
112.0 deg celsius
-
Winding Operating Current
1.2 amperes ac maximum single component single secondary
-
Body Width
0.890 inches minimum and 0.910 inches maximum
-
Winding Power Rating
101.8 volts-amperes single component single secondary