726903-1
Coils and Transformers
TRANSFORMER,POWER
726903-1
General Dynamics Ots Aerospace Inc.
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Operating Voltage
21.21 ac volts nominal single component all primary
-
Winding Power Rating
636.3 volts-amperes single component single primary
-
Body Length
0.766 inches minimum and 0.786 inches maximum
-
Winding Power Rating
225.0 volts-amperes single component single secondary
-
Maximum Operating Temp
122.0 deg celsius
-
Special Features
10 primary windings; 1 secondary winding
-
Mounting Method
tab single group
-
Winding Operating Voltage
106.05 ac volts nominal single component single secondary
-
Mounting Tab Width
0.007 inches minimum and 0.027 inches maximum
-
Overall Height
0.640 inches minimum and 0.660 inches maximum
-
Distance Between Mounting Facility Centers
0.787 inches minimum single mounting facility single center group and 0.807 inches maximum single mounting facility single center group
-
Inclosure Type
fully inclosed
-
Winding Operating Current
30.0 amperes ac maximum single component single primary
-
Features Provided
color coded lead
-
Reliability Indicator
not established
-
Frequency Rating
30.0 kilohertz nominal single component
-
Input-Output Phase Relationship
single phase to single phase single component
-
Terminal Type And Quantity
22 wire lead
-
Winding Function And Quantity
10 primary single component and 1 secondary single component
-
Winding Operating Current
1.5 amperes ac maximum single component single secondary
-
Body Width
0.766 inches minimum and 0.786 inches maximum