0032471-001
Circuit Breakers
CIRCUIT BREAKER
0032471-001
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac second location
-
Maximum Continuous Load Current Rating Per Pole
65.0 amperes ac fourth location
-
Circuit Protection Type
overcurrent all locations
-
Trip Release Method
magnetic all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
-
Manual Actuator Type And Quantity
4 toggle
-
Actuator Function
trip-reset
-
Actuator Position Designation
at each pole
-
Internal Trip Release Configuration
series trip fourth location
-
Internal Trip Release Configuration
series trip third location
-
Internal Trip Release Configuration
series trip w/remote trip feature second location
-
Nominal Thread Size
0.138 inches
-
Trip Release Duty Cycle
continuous first location
-
Switch Terminal Type
tab, solder lug
-
Switch Current Rating And Type In Amps
10.0 ac and 4.0 dc
-
Switch Voltage Rating And Type In Volts
250.0 ac and 30.0 dc
-
Terminal Type And Quantity
10 threaded stud
-
Body Style
8c multipole-multiple actuator type
-
Body Width
2.990 inches minimum and 3.010 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
1.928 inches minimum and 1.948 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
0.740 inches minimum and 0.760 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.052 inches minimum and 2.072 inches maximum
-
Switch Contact Arrangement
single pole, double throw
-
Boss Height
0.130 inches minimum and 0.150 inches maximum
-
Mounting Surface To Terminal End Distance
2.471 inches nominal
-
Pole Quantity
4
-
Mounting Facility Type And Quantity
8 threaded hole
-
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac first location
-
Thread Pitch Diameters
0.1177 to 0.1214 inches
-
Body Length
2.490 inches minimum and 2.510 inches maximum
-
Case Material
plastic
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.740 inches minimum and 0.760 inches maximum
-
Fragility Factor
moderately rugged
-
Arc Quenching Method
magnetic blowout
-
Storage Type
general purpose warehouse
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
65.0 amperes ac third location
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Auxiliary Trip Coil Voltage Type And Rating In Volts
115.0 ac nominal first location
-
Auxiliary Trip Coil Voltage Type And Rating In Volts
115.0 ac nominal second location
-
Trip Release Characteristic
time delay all locations
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
External Actuator Linkage Arrangement
one, two, three, and four linked
-
Auxiliary Switch Function And Quantity
1 alarm
-
Internal Trip Release Configuration
series trip w/remote trip feature first location
-
Trip Release Duty Cycle
continuous second location
-
Switch Location And Position Designation
external at pole four
-
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 minimum at 200 pct all locations and 8.000 maximum at 200 pct
-
Inclosure Protection Type For Which Designed
moisture resistant and salt water resistant and humidity resistant
-
Frequency In Hertz
50.0 all locations or 60.0
-
Thread Series Designator
unc