11-00094-001
Coils and Transformers
COIL,ELECTRICAL
11-00094-001
COIL,ELECTRICAL
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Terminal Type And Quantity
4 wire lead
-
Inductance Rating
0.725 millihenries minimum single component 1st winding and 1.09 millihenries maximum single component 1st winding
-
Rating Method
electrical single component all winding
-
Winding Operating Voltage
31.00 ac pounds per hour wet single component 2nd winding
-
Core Construction
s0lid single component
-
Dc Resistance Rating In Ohms
0.380 single component 1st winding
-
Winding Operating Current
2.5 amperes maximum of standard range b single component 1st winding
-
Inclosure Type
fully inclosed
-
Winding Operating Current
500.0 milliamperes maximum of standard range b single component 2nd winding
-
Dc Resistance Rating In Ohms
1.280 single component 2nd winding
-
Body Length
0.600 inches maximum
-
Winding Quantity
2 single component
-
Frequency Rating
100.0 kilohertz nominal single component
-
Reliability Indicator
not established
-
Mounting Method
terminal single group
-
Inductance Rating
2.89 millihenries minimum single component 2nd winding and 4.34 millihenries maximum single component 2nd winding
-
Test Data Document
16340-11-00094 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Overall Diameter
1.200 inches maximum
-
Winding Operating Voltage
17.00 ac pounds per hour wet single component 1st winding
-
Maximum Operating Temp
120.0 deg celsius