4010-1486-11

Filters and Networks

FILTER,BAND PASS

4010-1486-11

5915-01-324-5846

5915 - Filters and Networks

Southwest Research Institute

FILTER,BAND PASS

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Inclosure Type

    encased

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.414 inches nominal

  • Body Width

    0.614 inches nominal

  • Principal Circuitry Type Per Function

    inductance-capacitance blank

  • Voltage Standing Wave Ratio Frequency Limits Per Function

    30.0 megahertz blank and 620.0 megahertz blank

  • Body Material

    metal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.300 inches nominal

  • Overall Length

    1.800 inches nominal

  • Specified Frequencies Of Discrimination Per Function

    30.00 megahertz blank and 620.00 megahertz blank and 16.00 megahertz blank and 1.18 gigahertz blank

  • Insertion Loss At Reference Frequency Per Function In Decibels

    1.0 blank

  • Style Designator

    rectangular terminal/terminals on opposite surfaces

  • Frequency Band Width Per Function

    30.00 megahertz blank and 620.00 megahertz blank

  • Functional Terminal Type And Quantity

    1 connector, plug output 2nd function

  • Unthreaded Mounting Hole Diameter

    0.102 inches minimum and 0.110 inches maximum

  • Source Impedance Rating Per Function

    50.0 ohms blank

  • End Item Identification

    amplifier,radio am-6840a/srd-19

  • Operating Temp Range

    +0.0/+50.0 deg celsius

  • Load Impedance Per Function

    50.0 ohms blank

  • Average Life Rating In Hours

    5300000.0

  • Body Length

    1.500 inches nominal

  • Reference Frequency Per Function

    295.0 megahertz blank

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Functional Terminal Type And Quantity

    1 connector, plug input 1st function

  • Features Provided

    moisture resistant and shock resistant

  • Body Height

    0.400 inches nominal

  • Discrimination At Specified Frequencies Per Function In Decibels

    5.0 minimum blank and 30.0 maximum blank

  • Voltage Standing Wave Ratio Per Function

    1.5 blank

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...