380-10423-5
Circuit Breakers
CIRCUIT BREAKER
380-10423-5
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Operating Voltage Type And Rating Per Pole In Volts
200.0 ac single location and 28.0 dc single location
-
Overall Width
0.750 inches maximum
-
Trip Release Characteristic
time delay single location
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Specification/Standard Data
82918-380-10423 manufacturers source control
-
Frequency In Hertz
400.0 single location
-
Body Style
single pole type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location
-
Terminal Type And Quantity
2 tab w/screw
-
Center To Center Distance Between Terminals Parallel To Length
1.660 inches maximum
-
Case Material
plastic
-
Fragility Factor
moderately rugged
-
Inclosure Protection Type For Which Designed
shock resistant and vibration resistant
-
Thread Series Designator
unc
-
Reset Method
manual
-
Actuator Position Designation
at pole one
-
Overall Length
2.189 inches maximum
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Boss Height
0.235 inches minimum and 0.265 inches maximum
-
Trip Release Ambient Temp Rating
40.0 deg celsius nominal single location
-
Mounting Facility Type And Quantity
2 threaded hole
-
Thread Quantity Per Inch
32
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.796 inches minimum and 1.828 inches maximum
-
Mounting Surface To Terminal End Distance
2.000 inches maximum
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
thermal single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3000.0 ac single location and 2000.0 dc single location
-
Trip Delay Time In Seconds Per Rated Continuous Current
15.000 minimum at 200 pct single location and 55.000 maximum at 200 pct single location
-
Manual Actuator Type And Quantity
1 push-pull
-
Pole Quantity
1
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac single location and 5.0 amperes dc single location
-
Internal Trip Release Configuration
series trip single location
-
Nominal Thread Size
0.138 inches