T4886
Coils and Transformers
TRANSFORMER,POWER
T4886
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Reliability Indicator
not established
-
Overall Length
2.780 inches minimum and 2.785 inches maximum
-
Winding Operating Current
733.0 milliamperes ac nominal single component single secondary
-
Test Data Document
04939-717801569 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Winding Operating Voltage
22.70 ac volts nominal single component single secondary
-
Input-Output Phase Relationship
three phase to three phase single component
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Mounting Method
threaded hole all groupings
-
Inclosure Type
fully inclosed
-
Nominal Thread Size
0.112 inches all groupings
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.155 inches minimum single mounting facility all center groupings and 1.165 inches maximum single mounting facility all center groupings
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.395 inches minimum single mounting facility all center groupings and 2.405 inches maximum single mounting facility all center groupings
-
Thread Series Designator
unc all groupings
-
Winding Operating Voltage
200.00 ac volts nominal single component single primary
-
Overall Height
1.975 inches minimum and 2.025 inches maximum
-
Overall Width
1.530 inches minimum and 1.570 inches maximum
-
Thread Direction (Non-Core)
err-070
-
Transformer Winding Connection Type
delta-wye
-
Winding Shielding Method
internal shield brought out to terminal single component and internal shield grounded to mounting single component
-
Mounting Facility Quantity
4 all groupings
-
Terminal Type And Quantity
6 pin
-
Winding Power Rating
16.6 volts-amperes single component single secondary
-
Winding Power Rating
16.0 volts-amperes single component single primary
-
Cubic Measure (Non-Core)
8.85 cubic inches
-
Winding Operating Current
80.0 milliamperes ac nominal single component single primary
-
Frequency Rating
400.0 hertz nominal single component