11-00050-001
Coils and Transformers
TRANSFORMER,POWER
11-00050-001
General Dynamics Ots Aerospace Inc.
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Operating Current
192.0 milliamperes ac minimum single component 1st secondary and 240.0 milliamperes ac maximum single component 1st secondary
-
Winding Function And Quantity
1 primary single component and 3 secondary single component
-
Winding Operating Voltage
55.42 ac volts nominal single component 1st secondary
-
Winding Operating Current
48.0 milliamperes ac nominal single component 2nd secondary
-
Overall Length
1.530 inches minimum and 1.570 inches maximum
-
Winding Operating Voltage
19.79 ac volts nominal single component single primary
-
Winding Operating Voltage
19.79 ac volts nominal single component 3rd secondary
-
Winding Operating Voltage
27.71 ac volts nominal single component 2nd secondary
-
Input-Output Phase Relationship
single phase to single phase single component
-
Test Data Document
16340-11-00094 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Reliability Indicator
not established
-
Maximum Operating Temp
85.0 deg celsius
-
Terminal Type And Quantity
9 pin
-
Winding Operating Current
670.0 milliamperes ac nominal single component single primary
-
Winding Power Rating
0.5 volts-amperes single component 3rd secondary
-
Winding Power Rating
13.3 volts-amperes single component 1st secondary
-
Winding Operating Current
26.0 milliamperes ac nominal single component 3rd secondary
-
Body Height
0.650 inches minimum and 0.690 inches maximum
-
Winding Power Rating
13.2 volts-amperes single component single primary
-
Inclosure Type
fully inclosed
-
Winding Tap Location (Non-Core)
err-070
-
Mounting Tab Width
0.007 inches minimum and 0.027 inches maximum
-
Distance Between Mounting Facility Centers
1.073 inches minimum single mounting facility single center group and 1.093 inches maximum single mounting facility single center group
-
Overall Width
1.080 inches minimum and 1.120 inches maximum
-
Mounting Method
tab single group
-
Frequency Rating
114.0 kilohertz nominal single component
-
Winding Power Rating
1.3 volts-amperes single component 2nd secondary