203-111-22116-1
Circuit Breakers
CIRCUIT BREAKER
203-111-22116-1
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Type And Quantity
2 clip
-
Fragility Factor
moderately rugged
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.200 minimum at 200 pct first location and 1.700 maximum at 200 pct first location
-
Special Handling Feature
magnetic
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Maximum Continuous Load Current Rating Per Pole
500.0 milliamperes dc third location
-
Frequency In Hertz
50.0 second location or 60.0 second location
-
Reset Method
manual
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Body Length
2.000 inches nominal
-
Internal Trip Release Configuration
series trip all locations
-
Unpackaged Unit Weight
3.900 ounces
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac first location
-
Body Height
1.770 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
0.595 inches minimum and 0.655 inches maximum
-
Trip Release Method
magnetic all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc third location
-
Actuator Position Designation
at pole two
-
Boss Height
0.005 inches minimum and 0.155 inches maximum
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac first location
-
Body Style
multipole-single actuator type
-
Manual Actuator Type And Quantity
1 rotary
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac first location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac second location
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac second location
-
Main Contact Tripping Mechanism Type
trip free
-
Body Width
2.170 inches nominal
-
Inclosure Protection Type For Which Designed
shockproof and vibrationproof
-
Terminal Type And Quantity
6 quick disconnect, male
-
Frequency In Hertz
50.0 first location or 60.0 first location
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac second location
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.200 minimum at 200 pct second location and 1.700 maximum at 200 pct second location
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc third location
-
Case Material
plastic
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.500 minimum at 200 pct third location and 9.000 maximum at 200 pct third location