UPL1-1REC2-7996-5

Circuit Breakers

CIRCUIT BREAKER

UPL1-1REC2-7996-5

5925-01-326-0940

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    2 threaded stud

  • Thread Series Designator

    unc

  • Switch Voltage Rating And Type In Volts

    20.0 ac

  • Inclosure Protection Type For Which Designed

    fungus proof

  • Inclosure Protection Type For Which Designed

    dustproof and

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 maximum at 200 pct single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.600 minimum at 200 pct and

  • Nominal Thread Size

    0.138 inches

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Characteristic

    time delay single location

  • Trip Release Method

    magnetic single location

  • Circuit Protection Type

    overcurrent single location

  • Operating Voltage Type And Rating Per Pole In Volts

    65.0 dc single location

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes dc single location

  • Thread Quantity Per Inch

    32

  • Iii Storage Type

    general purpose warehouse

  • Switch Current Rating And Type In Amps

    5.0 ac

  • Switch Terminal Type

    tab, solder lug

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Iii Arc Quenching Method

    magnetic blowout

  • Boss Height

    0.165 inches maximum

  • Boss Height

    0.135 inches minimum and

  • Switch Contact Arrangement

    single pole, double throw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.070 inches maximum

  • Body Width

    0.750 inches nominal

  • Body Length

    2.500 inches maximum

  • Body Length

    2.480 inches minimum and

  • Body Style

    12a single pole type

  • Pole Quantity

    1

  • Mounting Surface To Terminal End Distance

    2.625 inches nominal

  • Iii Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and

  • Center To Center Distance Between Terminals Parallel To Length

    1.952 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.924 inches minimum and

  • Case Material

    plastic

  • Switch Location And Position Designation

    internal at pole one

  • Internal Trip Release Configuration

    series trip single location

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...