VE-40189
Coils and Transformers
TRANSFORMER,POWER
VE-40189
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Reliability Indicator
not established
-
Overall Height
1.350 inches maximum
-
Overall Width
2.300 inches maximum
-
Thread Class
2b
-
Thread Direction
right-hand
-
Hazardous Locations/Environmental Protection
vibration resistant
-
Overall Length
2.300 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.890 inches minimum and 1.910 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.240 inches minimum and 1.260 inches maximum
-
Input-Output Phase Relationship
single phase to single phase
-
Mounting Facility Quantity
4
-
Mounting Method
threaded hole
-
Nominal Thread Size
0.112 inches
-
Winding Tap Location
center tap
-
Winding Power Rating
344.1 volts-amperes
-
Winding Operating Voltage
10.96 ac volts nominal
-
Winding Operating Voltage
109.59 ac volts nominal
-
Special Features
one primary winding and five secondary windings;terminal 8 is a common center tap to windings one and two;terminal 13 is a common center tap to windings four and five
-
Frequency Rating
150.0 kilohertz nominal
-
Maximum Operating Temp
130.0 deg celsius
-
Inclosure Type
fully inclosed
-
Winding Function And Quantity
1 primary and 5 secondary
-
Winding Operating Current
141.4 milliamperes ac nominal
-
Winding Operating Current
31.4 amperes ac nominal
-
Winding Operating Current
36.8 amperes ac nominal
-
Winding Power Rating
15.5 volts-amperes
-
Winding Power Rating
317.2 volts-amperes
-
Winding Operating Voltage
219.17 ac volts nominal
-
Winding Operating Voltage
8.62 ac volts nominal
-
Test Data Document
82577-h940072 drawing
-
Thread Series Designator
unc
-
Terminal Type And Quantity
3 threaded hole and 12 pin