219-4-22134-1

Circuit Breakers

CIRCUIT BREAKER

219-4-22134-1

5925-01-328-5267

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Center To Center Distance Between Terminals Parallel To Width

    1.026 inches nominal

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac fourth location

  • Internal Trip Release Configuration

    series trip all locations

  • Body Length

    5.125 inches nominal

  • Body Width

    4.144 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac third location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.026 inches nominal

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    8 threaded hole

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • External Actuator Linkage Arrangement

    one, two, three, and four linked

  • Terminal Type And Quantity

    8 threaded stud

  • Nominal Thread Size

    0.138 inches

  • Frequency In Hertz

    60.0 all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac first location

  • Center To Center Distance Between Terminals Parallel To Length

    5.706 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac third location

  • Arc Quenching Method

    magnetic blowout

  • Mounting Surface To Terminal End Distance

    3.550 inches nominal

  • Inclosure Protection Type For Which Designed

    general purpose

  • Unpackaged Unit Weight

    2.438 pounds

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac first location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Boss Height

    0.220 inches nominal

  • Manual Actuator Type And Quantity

    4 toggle

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 200 pct all locations and 6.000 maximum at 200 pct all locations

  • Case Material

    plastic

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac second location

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac fourth location

  • Pole Quantity

    4

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac second location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...