6181559-014

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

6181559-014

5915-01-328-5854

5915 - Filters and Networks

Raytheon Company

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Functional Terminal Type And Quantity

    41 friction w/grounding strap and pin input-output

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 4th radio interference

  • Operating Temp Range

    -55.0/+125.0 deg celsius

  • Overall Width

    1.710 inches nominal

  • Power Line Frequency Rating Per Function In Hertz

    400.0 5th radio interference

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 6th radio interference

  • Operating Voltage Rating And Type Per Function

    800.0 volts dc 2nd radio interference 2nd function

  • Precious Material

    gold

  • Operating Voltage Rating And Type Per Function

    800.0 volts dc 3rd radio interference 3rd function

  • Body Material

    metal

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Input Terminal Manufacturer Code

    59610

  • Operating Current Rating Per Function In Amps

    5.0 6th radio interference

  • Special Features

    forty-one filtered functions with y-type insert position

  • Maximum Voltage Drop Per Function

    8.0 volts dc 3rd radio interference

  • Output Terminal Identification

    mil-c-26482

  • Maximum Voltage Drop Per Function

    8.0 volts dc 4th radio interference

  • Maximum Voltage Drop Per Function

    8.0 volts dc 5th radio interference

  • Load Impedance Per Function

    50.0 ohms 6th radio interference

  • Input Terminal Identification

    mil-c-26482

  • Body Surface Treatment

    cadmium

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Operating Current Rating Per Function In Amps

    5.0 2nd radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 5th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

  • Maximum Dielectric Withstanding Ac Rms Voltage

    1.2 kilovolts at sea level

  • Power Line Frequency Rating Per Function In Hertz

    400.0 1st radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • Maximum Voltage Drop Per Function

    2.5 volts ac 4th radio interference and 2.5 volts ac 6th radio interference and 2.5 volts ac 5th radio interference and 2.5 volts ac 3rd radio interference and 2.5 volts ac 2nd radio interference and 2.5 volts ac 1st radio interference and 8.0 volts dc

  • Operating Voltage Rating And Type Per Function

    250.0 volts ac 3rd radio interference 3rd function and 250.0 volts ac 5th radio interference 5th function and 250.0 volts ac 2nd radio interference 2nd function and 250.0 volts ac 1st radio interference 1st function and 250.0 volts ac 4th radio

  • ~1

    6th radio interference

  • ~1

    interference 4th function and 250.0 volts ac 6th radio

  • Maximum Temp Rise

    25.0 deg celsius

  • Operating Current Rating Per Function In Amps

    5.0 3rd radio interference

  • Output Terminal Manufacturer Code

    59610

  • Operating Voltage Rating And Type Per Function

    800.0 volts dc 1st radio interference 1st function

  • Operating Current Rating Per Function In Amps

    5.0 4th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 2nd radio interference

  • Overall Length

    2.187 inches nominal

  • Principal Circuitry Type Per Function

    inductance-capacitance 6th radio interference

  • Operating Current Rating Per Function In Amps

    5.0 5th radio interference

  • Full Load Minimum Insertion Loss At Specified Frequency In Decibels

    3.0 and 10.0 and 10.0 and 50.0 and 10.0 and 50.0

  • Power Line Frequency Rating Per Function In Hertz

    400.0 3rd radio interference

  • Operating Voltage Rating And Type Per Function

    800.0 volts dc 4th radio interference 4th function

  • Unthreaded Mounting Hole Diameter

    0.125 inches nominal

  • Operating Voltage Rating And Type Per Function

    800.0 volts dc 6th radio interference 6th function

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Vibration Resistance Range In Hertz

    +10.0/+500.0

  • Source Impedance Rating Per Function

    50.0 ohms 6th radio interference

  • Style Designator

    filter connector

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Maximum Dielectric Withstanding Dc Voltage

    1.2 kilovolts at sea level

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd radio interference

  • Overall Height

    1.710 inches nominal

  • Operating Current Rating Per Function In Amps

    5.0 1st radio interference

  • Maximum Voltage Drop Per Function

    8.0 volts dc 1st radio interference

  • Features Provided

    moisture resistant and shock resistant

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.271 inches nominal

  • Load Impedance Per Function

    50.0 ohms 5th radio interference

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.271 inches nominal

  • Full Load Insertion Loss Frequencies In Megahertz

    0.0 and 1.0 and 10.0 and 0.1 and 100.0 and 1000.0

  • Precious Material And Location

    contact surfaces gold

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th radio interference

  • Maximum Voltage Drop Per Function

    8.0 volts dc 2nd radio interference

  • Inclosure Type

    hermetically sealed

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...