6181559-016
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
6181559-016
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Operating Voltage Rating And Type Per Function
250.0 volts ac 2nd radio interference 2nd function and 250.0 volts ac 4th radio interference 4th function and 250.0 volts ac 5th radio interference 5th function and 250.0 volts ac 3rd radio interference 3rd function and 250.0 volts ac 1st radio
-
Maximum Voltage Drop Per Function
2.5 volts ac 1st radio interference and 2.5 volts ac 3rd radio interference and 2.5 volts ac 2nd radio interference and 2.5 volts ac 4th radio interference and 2.5 volts ac 5th radio interference and 2.5 volts ac 6th radio interference and 8.0 volts dc
-
Operating Current Rating Per Function In Amps
5.0 3rd radio interference
-
Operating Current Rating Per Function In Amps
5.0 6th radio interference
-
Source Impedance Rating Per Function
50.0 ohms 4th radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 4th radio interference
-
Operating Temp Range
-55.0/+125.0 deg celsius
-
Overall Width
1.710 inches nominal
-
Power Line Frequency Rating Per Function In Hertz
400.0 5th radio interference
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 6th radio interference
-
Operating Voltage Rating And Type Per Function
800.0 volts dc 2nd radio interference 2nd function
-
Output Terminal Manufacturer Code
59610
-
Operating Voltage Rating And Type Per Function
800.0 volts dc 1st radio interference 1st function
-
Operating Current Rating Per Function In Amps
5.0 4th radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 2nd radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 6th radio interference
-
Operating Current Rating Per Function In Amps
5.0 5th radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 3rd radio interference
-
Input Terminal Manufacturer Code
59610
-
Functional Terminal Type And Quantity
61 friction w/grounding strap and pin input-output
-
Precious Material
gold
-
Operating Voltage Rating And Type Per Function
800.0 volts dc 3rd radio interference 3rd function
-
Source Impedance Rating Per Function
50.0 ohms 5th radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Operating Voltage Rating And Type Per Function
800.0 volts dc 4th radio interference 4th function
-
Unthreaded Mounting Hole Diameter
0.125 inches nominal
-
Overall Height
1.701 inches nominal
-
Overall Length
2.282 inches nominal
-
Full Load Insertion Loss Frequencies In Megahertz
100.0 and 1.0 and 0.0 and 0.1 and 10.0 and 1000.0
-
Operating Voltage Rating And Type Per Function
800.0 volts dc 6th radio interference 6th function
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Vibration Resistance Range In Hertz
+10.0/+500.0
-
Source Impedance Rating Per Function
50.0 ohms 6th radio interference
-
Style Designator
filter connector
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Maximum Dielectric Withstanding Dc Voltage
1.2 kilovolts at sea level
-
Load Impedance Per Function
50.0 ohms 4th radio interference
-
Body Material
aluminum
-
Mounting Facility Type And Quantity
4 unthreaded hole
-
Principal Circuitry Type Per Function
inductance-capacitance 3rd radio interference
-
Operating Current Rating Per Function In Amps
5.0 1st radio interference
-
Maximum Voltage Drop Per Function
8.0 volts dc 1st radio interference
-
Full Load Minimum Insertion Loss At Specified Frequency In Decibels
10.0 and 10.0 and 50.0 and 10.0 and 3.0 and 50.0
-
Maximum Temp Rise
25.0 deg celsius
-
~1
interference 1st function and 250.0 volts ac 6th radio
-
~1
5th radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 1st radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference
-
Features Provided
moisture resistant and shock resistant
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.271 inches nominal
-
Load Impedance Per Function
50.0 ohms 5th radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.271 inches nominal
-
Precious Material And Location
contact surfaces gold
-
Principal Circuitry Type Per Function
inductance-capacitance 4th radio interference
-
Maximum Voltage Drop Per Function
8.0 volts dc 2nd radio interference
-
Inclosure Type
hermetically sealed
-
Maximum Voltage Drop Per Function
8.0 volts dc 3rd radio interference
-
Output Terminal Identification
mil-c-26482
-
Special Features
sixty-one filtered functions with n-type insert position
-
Maximum Voltage Drop Per Function
8.0 volts dc 4th radio interference
-
Load Impedance Per Function
50.0 ohms 6th radio interference
-
Input Terminal Identification
mil-c-26482
-
Body Surface Treatment
cadmium
-
Maximum Voltage Drop Per Function
8.0 volts dc 6th radio interference
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Operating Current Rating Per Function In Amps
5.0 2nd radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 5th radio interference
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Maximum Dielectric Withstanding Ac Rms Voltage
1.2 kilovolts at sea level