52-485-002
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
52-485-002
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Power Line Frequency Rating Per Function In Hertz
60.0 2nd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Operating Current Rating Per Function In Amps
20.0 1st radio interference
-
Power Line Frequency Rating Per Function In Hertz
60.0 3rd radio interference
-
Inclosure Type
hermetically sealed
-
Overall Length
8.930 inches nominal
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Operating Temp Range
-55.0/+85.0 deg celsius
-
Features Provided
mounting bracket
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference
-
Operating Current Rating Per Function In Amps
20.0 2nd radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
5.000 inches nominal
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Special Features
three filtered functions
-
Functional Terminal Type And Quantity
3 threaded stud output 2nd function
-
Maximum Voltage Drop Per Function
1.15 volts ac 3rd radio interference
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 2nd radio interference 2nd function
-
Body Height
4.000 inches nominal
-
Input Terminal Identification
3315
-
Body Width
3.500 inches nominal
-
Principal Circuitry Type Per Function
inductance-capacitance 3rd radio interference
-
Power Line Frequency Rating Per Function In Hertz
60.0 1st radio interference
-
Mounting Facility Screw Thread Series Designator
unc
-
Nominal Thread Size
0.164 inches
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 3rd radio interference 3rd function
-
Full Load Minimum Insertion Loss At Specified Frequency In Decibels
21.0 and 13.0 and 21.0 and 40.0 and 57.0 and 40.0
-
Maximum Voltage Drop Per Function
1.15 volts ac 2nd radio interference
-
Full Load Insertion Loss Frequencies In Megahertz
100.0 and 0.3 and 1.0 and 0.15 and 10.0 and 1000.0
-
Operating Current Rating Per Function In Amps
20.0 3rd radio interference
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Body Surface Treatment
tin
-
Mounting Facility Type And Quantity
1 bracket
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
2.500 inches nominal
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 1st radio interference 1st function
-
Body Length
8.000 inches nominal
-
Mounting Facility Type And Quantity
4 threaded hole
-
Body Material
metal
-
Functional Terminal Type And Quantity
1 connector, receptacle input 1st function
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Maximum Voltage Drop Per Function
1.15 volts ac 1st radio interference
-
Input Terminal Manufacturer Code
33095
-
Load Impedance Per Function
50.0 ohms 3rd radio interference