M27/326-05

Coils and Transformers

TRANSFORMER,POWER

M27/326-05

5950-01-329-9517

5950 - Coils and Transformers

Military Specifications

TRANSFORMER,POWER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • ~1

    data on certain environmental and performance r

  • Center To Center Distance Between Mounting Facilities Parallel To Width

    1.234 inches minimum single mounting facility single center group and 1.266 inches maximum single mounting facility single center group

  • Reliability Indicator

    not established

  • Input-Output Phase Relationship

    single phase to single phase single component

  • Winding Operating Voltage

    115.00 ac volts nominal single component single primary

  • Overall Height

    2.813 inches nominal

  • Maximum Operating Temp

    130.0 deg celsius

  • Inclosure Type

    hermetically sealed

  • Thread Series Designator

    unc single group

  • Overall Width

    1.687 inches minimum and 1.812 inches maximum

  • Terminal Type And Quantity

    6 wire hook

  • Winding Operating Voltage

    12.00 ac volts nominal single component 1st secondary

  • Thread Direction (Non-Core)

    err-070

  • Nominal Thread Size

    0.138 inches single group

  • Mounting Facility Quantity

    4 single group

  • Frequency Rating

    50.0 hertz nominal single component or 60.0 hertz nominal single component

  • Winding Shielding Method

    core grounded single component

  • Center To Center Distance Between Mounting Facilities Parallel To Length

    1.359 inches minimum single mounting facility single center group and 1.391 inches maximum single mounting facility single center group

  • Overall Length

    1.813 inches minimum and 1.938 inches maximum

  • Winding Operating Current

    400.0 milliamperes ac nominal single component 1st secondary

  • Winding Power Rating

    5.0 volts-amperes single component 1st secondary

  • Mounting Method

    threaded stud single group

  • Winding Function And Quantity

    1 primary single component and 2 secondary single component

  • Specification/Standard Data

    81349-mil-t-27/326 government specification

  • Dummy Terminal Quantity (Non-Core)

    1

  • Unpackaged Unit Weight (Non-Core)

    1.200 pounds

  • Test Data Document

    81349-mil-t-27 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...