TB13025BWE05LL

Circuit Breakers

CIRCUIT BREAKER

TB13025BWE05LL

5925-01-330-8609

5925 - Circuit Breakers

General Electric Co

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Width

    4.875 inches nominal

  • Body Height

    3.625 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    200000.0 ac all locations

  • Actuator Function

    trip-reset

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Body Length

    10.316 inches nominal

  • Storage Type

    general purpose warehouse

  • Unthreaded Mounting Hole Diameter

    0.196 inches nominal

  • Reset Method

    manual

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Special Handling Feature

    magnetic

  • Trip Release Characteristic

    instantaneous all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    8.938 inches nominal

  • Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.376 inches nominal

  • Case Material

    plastic

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 all locations

  • Boss Height

    0.219 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Main Contact Tripping Mechanism Type

    trip free

  • Terminal Type And Quantity

    6 compression

  • Center To Center Distance Between Terminals Parallel To Length

    9.250 inches nominal

  • Frequency In Hertz

    60.0 all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Body Style

    multipole-single actuator type

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Actuator Position Designation

    at pole two

  • Trip Release Method

    thermal-magnetic all locations

  • Center To Center Distance Between Terminals Parallel To Width

    1.375 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...