CD5-Z14-1

Circuit Breakers

CIRCUIT BREAKER

CD5-Z14-1

5925-01-330-8678

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 minimum at 200 pct second location and 100.000 maximum at 200 pct second location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 dc fifth location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.016 inches minimum and 1.036 inches maximum

  • Boss Height

    0.209 inches minimum and 0.229 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 minimum at 200 pct first location and 100.000 maximum at 200 pct first location

  • Thread Quantity Per Inch

    32

  • Mounting Surface To Terminal End Distance

    3.475 inches minimum and 3.495 inches maximum

  • Internal Trip Release Configuration

    series/relay trip first location

  • Internal Trip Release Configuration

    series trip fifth location

  • Frequency In Hertz

    60.0 first location

  • Trip Release Method

    magnetic-hydraulic all locations

  • Body Length

    4.740 inches minimum and 4.760 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 dc fourth location

  • Body Style

    multipole-multiple actuator type

  • Frequency In Hertz

    60.0 second location

  • Fragility Factor

    moderately rugged

  • Circuit Protection Type

    overcurrent all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac third location

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac first location

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac first location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 minimum at 200 pct third location and 100.000 maximum at 200 pct third location

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Auxiliary Trip Coil Voltage Type And Rating In Volts

    25.0 dc nominal first location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    25.000 minimum at 200 pct fifth location and 95.000 maximum at 200 pct fifth location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac second location

  • Center To Center Distance Between Terminals Parallel To Length

    3.537 inches minimum and 3.557 inches maximum

  • Internal Trip Release Configuration

    series trip fourth location

  • Inclosure Protection Type For Which Designed

    vibration resistant and shock resistant and moisture resistant and salt spray proof

  • Mounting Facility Type And Quantity

    10 threaded hole and 5 slot

  • Internal Trip Release Configuration

    series trip second location

  • External Actuator Linkage Arrangement

    one, two, three, four, and five linked

  • Nominal Thread Size

    0.138 inches

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac second location

  • Internal Trip Release Configuration

    series trip third location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac first location

  • Special Features

    full length barriers between poles included

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Trip Delay Time In Seconds Per Rated Continuous Current

    25.000 minimum at 200 pct fourth location and 95.000 maximum at 200 pct fourth location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.740 inches minimum and 2.760 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    1.016 inches minimum and 1.036 inches maximum

  • Terminal Type And Quantity

    12 threaded stud

  • Frequency In Hertz

    60.0 third location

  • Operating Voltage Type And Rating Per Pole In Volts

    140.0 dc fifth location

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes dc fifth location

  • Pole Quantity

    5

  • Trip Release Duty Cycle

    continuous first location

  • Operating Voltage Type And Rating Per Pole In Volts

    140.0 dc fourth location

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes dc fourth location

  • Mounting Slot Width

    0.164 inches nominal

  • Body Width

    5.180 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac third location

  • Manual Actuator Type And Quantity

    5 toggle

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac third location

  • Case Material

    plastic

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac second location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...