Technical Characteristics
-
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 minimum at 200 pct second location and 100.000 maximum at 200 pct second location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 dc fifth location
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.016 inches minimum and 1.036 inches maximum
-
Boss Height
0.209 inches minimum and 0.229 inches maximum
-
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 minimum at 200 pct first location and 100.000 maximum at 200 pct first location
-
Thread Quantity Per Inch
32
-
Mounting Surface To Terminal End Distance
3.475 inches minimum and 3.495 inches maximum
-
Internal Trip Release Configuration
series/relay trip first location
-
Internal Trip Release Configuration
series trip fifth location
-
Frequency In Hertz
60.0 first location
-
Trip Release Method
magnetic-hydraulic all locations
-
Body Length
4.740 inches minimum and 4.760 inches maximum
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 dc fourth location
-
Body Style
multipole-multiple actuator type
-
Frequency In Hertz
60.0 second location
-
Fragility Factor
moderately rugged
-
Circuit Protection Type
overcurrent all locations
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac third location
-
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac first location
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac first location
-
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 minimum at 200 pct third location and 100.000 maximum at 200 pct third location
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Auxiliary Trip Coil Voltage Type And Rating In Volts
25.0 dc nominal first location
-
Trip Delay Time In Seconds Per Rated Continuous Current
25.000 minimum at 200 pct fifth location and 95.000 maximum at 200 pct fifth location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac second location
-
Center To Center Distance Between Terminals Parallel To Length
3.537 inches minimum and 3.557 inches maximum
-
Internal Trip Release Configuration
series trip fourth location
-
Inclosure Protection Type For Which Designed
vibration resistant and shock resistant and moisture resistant and salt spray proof
-
Mounting Facility Type And Quantity
10 threaded hole and 5 slot
-
Internal Trip Release Configuration
series trip second location
-
External Actuator Linkage Arrangement
one, two, three, four, and five linked
-
Nominal Thread Size
0.138 inches
-
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac second location
-
Internal Trip Release Configuration
series trip third location
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac first location
-
Special Features
full length barriers between poles included
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Trip Delay Time In Seconds Per Rated Continuous Current
25.000 minimum at 200 pct fourth location and 95.000 maximum at 200 pct fourth location
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.740 inches minimum and 2.760 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
1.016 inches minimum and 1.036 inches maximum
-
Terminal Type And Quantity
12 threaded stud
-
Frequency In Hertz
60.0 third location
-
Operating Voltage Type And Rating Per Pole In Volts
140.0 dc fifth location
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes dc fifth location
-
Pole Quantity
5
-
Trip Release Duty Cycle
continuous first location
-
Operating Voltage Type And Rating Per Pole In Volts
140.0 dc fourth location
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes dc fourth location
-
Mounting Slot Width
0.164 inches nominal
-
Body Width
5.180 inches maximum
-
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac third location
-
Manual Actuator Type And Quantity
5 toggle
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac third location
-
Case Material
plastic
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac second location