APGN-662-22005-6

Circuit Breakers

CIRCUIT BREAKER

APGN-662-22005-6

5925-01-330-9211

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Pitch Diameters

    0.4752 to 0.4787 inches

  • Body Style

    1b multipole-single actuator type

  • Body Length

    1.985 inches minimum and 2.015 inches maximum

  • Case Material

    metal

  • Nonturn Device Location

    at 12 oclock

  • Nonturn Device Radius

    0.641 inches minimum and 0.671 inches maximum

  • Nonturn Device Length

    0.115 inches minimum and 0.145 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3500.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip second location

  • Internal Trip Release Configuration

    series trip w/remote trip feature third location

  • Trip Release Duty Cycle

    continuous third location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.130 minimum at 200 pct all locations and 3.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    corrosion resistant and moisture resistant and salt spray proof and shock resistant and vibration resistant

  • Frequency In Hertz

    50.0 all locations or 60.0

  • Thread Series Designator

    un

  • Terminal Type And Quantity

    7 tab w/screw

  • Bushing Length

    0.610 inches minimum and 0.640 inches maximum

  • Body Width

    2.235 inches minimum and 2.265 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.515 inches minimum and 1.545 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.735 inches minimum and 0.765 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    2.232 inches maximum

  • Pole Quantity

    3

  • Special Handling Feature

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Auxiliary Trip Coil Voltage Type And Rating In Volts

    115.0 ac nominal third location

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole two

  • Internal Trip Release Configuration

    series trip first location

  • Nominal Thread Size

    0.500 inches

  • Unpackaged Unit Weight

    9.000 ounces

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...