5006-0036

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

5006-0036

5915-01-331-4073

5915 - Filters and Networks

Spectrum Control Inc.

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • End Item Identification

    tactical air operations module

  • Source Impedance Rating Per Function

    2.0 kilohms 2nd radio interference

  • Source Impedance Rating Per Function

    2.0 kilohms 3rd radio interference

  • Maximum Voltage Drop Per Function

    50.0 millivolts ac 2nd radio interference

  • Unpackaged Unit Weight

    1.800 pounds

  • Source Impedance Rating Per Function

    2.0 kilohms 4th radio interference

  • Maximum Voltage Drop Per Function

    50.0 millivolts ac 3rd radio interference

  • Maximum Voltage Drop Per Function

    50.0 millivolts ac 4th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    5000.0 1st radio interference

  • Body Surface Treatment

    tin

  • Full Load Insertion Loss Frequencies In Megahertz

    10.0 and 100.0 and 0.0 and 0.1 and 1.0 and 1000.0

  • Body Length

    5.230 inches minimum and 5.250 inches maximum

  • Operating Voltage Rating And Type Per Function

    5.0 volts ac 1st radio interference 1st function

  • Load Impedance Per Function

    2.0 kilohms 1st radio interference

  • Body Material

    metal

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    5000.0 2nd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    5000.0 3rd radio interference

  • Operating Temp Range

    -54.0/+65.0 deg celsius

  • Functional Terminal Type And Quantity

    2 threaded stud ground 3rd function

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th radio interference

  • Inclosure Type

    hermetically sealed

  • Operating Current Rating Per Function In Amps

    1.0 3rd radio interference

  • Operating Voltage Rating And Type Per Function

    5.0 volts ac 3rd radio interference 3rd function

  • Functional Terminal Type And Quantity

    4 threaded stud output 2nd function

  • Operating Voltage Rating And Type Per Function

    5.0 volts ac 4th radio interference 4th function

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.340 inches minimum and 1.360 inches maximum

  • Operating Current Rating Per Function In Amps

    1.0 4th radio interference

  • Source Impedance Rating Per Function

    2.0 kilohms 1st radio interference

  • Maximum Voltage Drop Per Function

    50.0 millivolts ac 1st radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • Features Provided

    fungus resistant and shock resistant

  • Functional Terminal Type And Quantity

    4 threaded stud input 1st function

  • Power Line Frequency Rating Per Function In Hertz

    5000.0 4th radio interference

  • Special Features

    four filtered functions

  • Body Height

    1.750 inches minimum and 1.770 inches maximum

  • Operating Current Rating Per Function In Amps

    1.0 1st radio interference

  • Style Designator

    rectangular terminal/terminals on opposite surfaces

  • Load Impedance Per Function

    2.0 kilohms 2nd radio interference

  • Vibration Resistance Range In Hertz

    +10.0/+500.0

  • Maximum Dielectric Withstanding Dc Voltage

    500.0 volts at sea level

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Average Life Rating In Hours

    1000.0

  • Load Impedance Per Function

    2.0 kilohms 3rd radio interference

  • Load Impedance Per Function

    2.0 kilohms 4th radio interference

  • Body Width

    1.750 inches minimum and 1.770 inches maximum

  • Overall Length

    6.590 inches minimum and 6.650 inches maximum

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd radio interference

  • Operating Voltage Rating And Type Per Function

    5.0 volts ac 2nd radio interference 2nd function

  • Full Load Minimum Insertion Loss At Specified Frequency In Decibels

    100.0 and 78.0 and 1.5 and 3.0 and 78.0 and 100.0

  • Mounting Facility Screw Thread Series Designator

    unc

  • Nominal Thread Size

    0.164 inches

  • Operating Current Rating Per Function In Amps

    1.0 2nd radio interference

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...