601301
Coils and Transformers
TRANSFORMER,POWER
601301
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Operating Current
200.0 milliamperes dc nominal single component single secondary
-
Winding Operating Voltage
14.00 dc volts nominal single component single secondary
-
Terminal Type And Quantity
5 pin
-
Input-Output Phase Relationship
single phase to single phase single component
-
Overall Diameter
0.765 inches maximum
-
Mounting Method
terminal single group
-
Body Length
0.560 inches maximum
-
Reliability Indicator
not established
-
Hazardous Locations/Environmental Protection
moisture resistant and vibration resistant
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Inclosure Type
fully inclosed
-
Winding Operating Voltage
160.00 dc volts nominal single component single primary
-
Special Features
primary terminal grounded to core
-
Test Data Document
13499-672-0535 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Frequency Rating
50.0 kilohertz nominal single component
-
Winding Shielding Method
core grounded single component