41-2-S14-LN2-20A

Circuit Breakers

CIRCUIT BREAKER

41-2-S14-LN2-20A

5925-01-332-2614

5925 - Circuit Breakers

Oakland Industries Ltd

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac single location and 20.0 amperes dc single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Trip Release Characteristic

    instantaneous single location

  • Thread Series Designator

    un

  • Body Length

    1.140 inches nominal

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

  • Bushing Length

    0.250 inches nominal

  • Special Handling Feature

    magnetic

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Reset Method

    manual

  • Nominal Thread Size

    0.500 inches

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Nonturn Device Width

    0.110 inches nominal

  • Nonturn Device Location

    at 12 oclock

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Manual Actuator Type And Quantity

    1 push-pull

  • Pole Quantity

    1

  • Mounting Surface To Terminal End Distance

    2.300 inches nominal

  • Internal Trip Release Configuration

    series trip single location

  • Center To Center Distance Between Terminals Parallel To Length

    0.790 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location and 28.0 dc single location

  • Nonturn Device Length

    0.060 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Body Style

    single pole type

  • Inclosure Protection Type For Which Designed

    vibration resistant and humidity resistant and corrosion resistant and fungus resistant

  • Frequency In Hertz

    60.0 single location

  • Body Width

    0.570 inches nominal

  • Nonturn Device Radius

    0.370 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...