ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Distance Between Mounting Facility Centers
1.690 inches minimum single mounting facility single center group and 1.710 inches maximum single mounting facility single center group
-
Inductance Rating
200.00 microhenries nominal single component single winding
-
Mounting Hole Diameter
0.155 inches minimum single group and 0.161 inches maximum single group
-
Maximum Operating Temp
130.0 deg celsius
-
Body Height
0.950 inches maximum
-
Rating Method
electrical single component single winding
-
Coil Form Type
solid single component
-
Body Width
1.330 inches maximum
-
Reliability Indicator
not established
-
Terminal Type And Quantity
2 wire lead
-
Mounting Method
unthreaded hole single group
-
Overall Length
2.370 inches minimum and 2.430 inches maximum
-
Unpackaged Unit Weight (Non-Core)
88.0 grams
-
Inclosure Type
fully inclosed
-
Winding Operating Current
5.5 amperes maximum of standard range b and better drop siding single component single winding
-
Frequency At Which Inductance And Quality Factor Applies (Non-Core)
150.0 kilohertz single component single winding
-
Core Construction
s0lid single component
-
Mounting Facility Quantity
2 single group
-
Test Data Document
82577-h940031 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)