Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Length

    3.537 inches minimum and 3.557 inches maximum

  • Body Width

    2.072 inches maximum

  • Nominal Thread Size

    0.138 inches

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.740 inches minimum and 2.760 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    1.016 inches minimum and 1.036 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    140.0 dc all locations

  • Manual Actuator Type And Quantity

    2 toggle

  • Trip Delay Time In Seconds Per Rated Continuous Current

    21.000 minimum at 200 pct all locations and 100.000 maximum at 200 pct all locations

  • Terminal Type And Quantity

    4 threaded stud

  • External Actuator Linkage Arrangement

    one and two linked

  • Mounting Facility Type And Quantity

    4 threaded hole and 2 slot

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 dc all locations

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Mounting Slot Width

    0.154 inches minimum and 0.174 inches maximum

  • Internal Trip Release Configuration

    series trip all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.016 inches minimum and 1.036 inches maximum

  • Boss Height

    0.209 inches minimum and 0.229 inches maximum

  • Thread Quantity Per Inch

    32

  • Mounting Surface To Terminal End Distance

    3.475 inches minimum and 3.495 inches maximum

  • Body Length

    4.740 inches minimum and 4.760 inches maximum

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Inclosure Protection Type For Which Designed

    moisture resistant and vibration resistant and shock resistant and salt spray proof

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes dc all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...