0485-4095-00
Coils and Transformers
TRANSFORMER,POWER
0485-4095-00
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Reliability Indicator
not established
-
Input-Output Phase Relationship
single phase to single phase single component
-
Body Length
0.718 inches maximum
-
Winding Operating Current
272.0 milliamperes ac nominal single component 2nd secondary
-
Winding Operating Voltage
10.59 ac volts nominal single component 1st secondary
-
Winding Operating Voltage
11.29 ac volts nominal single component 2nd secondary
-
Winding Operating Voltage
115.00 ac volts nominal single component all primary
-
Frequency Rating
50.0 hertz nominal or 60.0 hertz nominal single component
-
~1
brought out to terminal single component
-
Winding Shielding Method
internal shield brought out to terminal and internal shield grounded to core and
-
Body Outside Diameter
2.219 inches maximum
-
Inclosure Type
fully inclosed
-
Mounting Method
terminal single group
-
Winding Function And Quantity
2 primary and 2 secondary single component
-
Winding Operating Current
210.0 milliamperes ac nominal single component all primary
-
Winding Operating Current
4.4 amperes ac nominal single component 1st secondary
-
Terminal Type And Quantity
11 wire lead