TKJL110709-53

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

TKJL110709-53

5915-01-334-4795

5915 - Filters and Networks

Itt Cannon Electric

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Overall Length

    1.903 inches maximum

  • Overall Height

    1.708 inches maximum

  • Overall Width

    1.708 inches maximum

  • Unthreaded Mounting Hole Diameter

    0.142 inches minimum and

  • Unthreaded Mounting Hole Diameter

    0.157 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.375 inches nominal

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Load Impedance Per Function

    50.0 ohms 5th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 5th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 6th radio interference

  • Operating Current Rating Per Function In Amps

    5.0 5th radio interference

  • Operating Current Rating Per Function In Amps

    5.0 6th radio interference

  • Iii Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • Iii Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Iii Principal Circuitry Type Per Function

    inductance-capacitance 4th radio interference

  • Iii Operating Temp Range

    -55.0 to 125.0 deg celsius

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 6th radio interference

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Load Impedance Per Function

    50.0 ohms 6th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 1st radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 2nd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 3rd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 4th radio interference

  • Operating Current Rating Per Function In Amps

    5.0 1st radio interference

  • Operating Current Rating Per Function In Amps

    5.0 2nd radio interference

  • Operating Current Rating Per Function In Amps

    5.0 3rd radio interference

  • Operating Current Rating Per Function In Amps

    5.0 4th radio interference

  • Iii Principal Circuitry Type Per Function

    inductance-capacitance 3rd radio interference

  • Iii Maximum Temp Rise

    25.0 deg celsius

  • Functional Terminal Type And Quantity

    35 friction w/grounding strap and pin input-output

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 2nd radio interference and

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 5th radio interference and

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 6th radio interference and

  • Operating Voltage Rating And Type Per Function

    200.0 volts dc 1st radio interference

  • Operating Voltage Rating And Type Per Function

    200.0 volts dc 4th radio interference

  • Operating Voltage Rating And Type Per Function

    200.0 volts dc 5th radio interference

  • Operating Voltage Rating And Type Per Function

    200.0 volts dc 6th radio interference

  • Iii Body Material

    aluminum

  • Iii Maximum Dielectric Withstanding Dc Voltage

    500.0 volts at sea level

  • Iii Principal Circuitry Type Per Function

    inductance-capacitance 5th radio interference

  • Iii Principal Circuitry Type Per Function

    inductance-capacitance 6th radio interference

  • Inclosure Type

    encased

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 1st radio interference and

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 3rd radio interference and

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 4th radio interference and

  • Operating Voltage Rating And Type Per Function

    200.0 volts dc 2nd radio interference

  • Operating Voltage Rating And Type Per Function

    200.0 volts dc 3rd radio interference

  • Iii Body Surface Treatment

    cadmium

  • Special Features

    thirty five filtered functions

  • Style Designator

    46 filter connector

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...