AQB-A250-225N

Circuit Breakers

CIRCUIT BREAKER

AQB-A250-225N

5925-01-335-7098

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Quantity Per Inch

    20

  • Adjustable Trip Setting Current Range Per Pole In Amps

    +650.0/+1300.0 ac all locations

  • Inclosure Protection Type For Which Designed

    dustproof and fungus proof

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    3.000 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac all locations and 10000.0 dc all locations

  • Arc Quenching Method

    magnetic blowout

  • Frequency In Hertz

    400.0 all locations

  • Specification/Standard Data

    81349-mil-c-17361/6 government specification

  • Mounting Facility Type And Quantity

    4 threaded stud

  • Nominal Thread Size

    0.250 inches

  • Maximum Continuous Load Current Rating Per Pole

    250.0 amperes ac all locations and 250.0 amperes dc all locations

  • Case Material

    plastic

  • Terminal Type And Quantity

    6 threaded stud

  • ~1

    data on certain environmental and performanc

  • Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    9.875 inches nominal

  • Trip Release Characteristic

    instantaneous all locations

  • Mounting Surface To Terminal End Distance

    9.281 inches nominal

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Features Provided

    adjustable trip release

  • Center To Center Distance Between Terminals Parallel To Length

    9.875 inches nominal

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    500.0 ac all locations and 355.0 dc all locations

  • Body Width

    9.000 inches maximum

  • Trip Release Method

    magnetic all locations

  • Center To Center Distance Between Terminals Parallel To Width

    3.000 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Actuator Position Designation

    at pole two

  • Body Style

    multipole-single actuator type

  • Boss Height

    0.250 inches nominal

  • Body Length

    11.000 inches maximum

  • Manual Actuator Type And Quantity

    1 toggle

  • Test Data Document

    81349-mil-c-17361 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...