5114-1802-1

Circuit Breakers

CIRCUIT BREAKER

5114-1802-1

5925-01-336-7583

5925 - Circuit Breakers

Nordam Group Inc. The

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Mounting Surface To Terminal End Distance

    1.950 inches nominal

  • Fragility Factor

    moderately rugged

  • Bushing Length

    0.380 inches nominal

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Trip Release Method

    magnetic all locations

  • Actuator Position Designation

    at pole two

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Nonturn Device Location

    at 3 oclock and at 9 oclock

  • Specification/Standard Data

    29957-5114-1802 manufacturers specification control

  • Body Style

    multipole-single actuator type

  • Nonturn Device Radius

    0.625 inches nominal

  • Case Material

    metal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Body Width

    1.937 inches nominal

  • Frequency In Hertz

    400.0 all locations

  • Thread Series Designator

    unef

  • Terminal Type And Quantity

    6 tab w/screw

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 200 pct all locations and 9.000 maximum at 200 pct all locations

  • Body Length

    1.562 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...