21-522015-202
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
21-522015-202
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Principal Circuitry Type Per Function
inductance-capacitance 5th radio interference
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Operating Current Rating Per Function In Amps
3.0 1st radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference
-
Maximum Temp Rise
25.0 deg celsius
-
Output Terminal Manufacturer Code
89954
-
Mounting Facility Type And Quantity
4 slot
-
Principal Circuitry Type Per Function
inductance-capacitance 6th radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
0.906 inches minimum and 0.969 inches maximum
-
Source Impedance Rating Per Function
50.0 ohms 4th radio interference
-
Operating Temp Range
-55.0/+125.0 deg celsius
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.906 inches minimum and 0.969 inches maximum
-
Operating Current Rating Per Function In Amps
3.0 2nd radio interference
-
Input Terminal Manufacturer Code
89954
-
Body Material
metal
-
Source Impedance Rating Per Function
50.0 ohms 5th radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Operating Current Rating Per Function In Amps
3.0 3rd radio interference
-
Special Features
twenty filtered functions; two grounded contacts; four unfiltered contacts; 15-19 type insert arrangement
-
Maximum Voltage Drop Per Function
2.6 volts dc 4th radio interference
-
Maximum Voltage Drop Per Function
2.6 volts dc 5th radio interference
-
Maximum Voltage Drop Per Function
2.6 volts dc 6th radio interference
-
Overall Width
1.209 inches minimum and 1.229 inches maximum
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Load Impedance Per Function
50.0 ohms 5th radio interference
-
Full Load Insertion Loss Frequencies In Megahertz
100.0 and 0.0 and 10.0 and 1.0 and 0.1 and 1000.0
-
Functional Terminal Type And Quantity
26 friction w/grounding strap and pin input-output
-
Operating Voltage Rating And Type Per Function
260.0 volts dc 2nd radio interference 2nd function
-
Principal Circuitry Type Per Function
inductance-capacitance 4th radio interference
-
Inclosure Type
hermetically sealed
-
Overall Length
1.719 inches nominal
-
Operating Voltage Rating And Type Per Function
260.0 volts dc 3rd radio interference 3rd function
-
Operating Voltage Rating And Type Per Function
260.0 volts dc 4th radio interference 4th function
-
Output Terminal Identification
mil-c-38999
-
Load Impedance Per Function
50.0 ohms 6th radio interference
-
Operating Voltage Rating And Type Per Function
260.0 volts dc 5th radio interference 5th function
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Input Terminal Identification
mil-c-38999
-
Operating Voltage Rating And Type Per Function
260.0 volts dc 6th radio interference 6th function
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Operating Current Rating Per Function In Amps
3.0 4th radio interference
-
Source Impedance Rating Per Function
50.0 ohms 6th radio interference
-
Operating Current Rating Per Function In Amps
3.0 5th radio interference
-
Style Designator
filter connector
-
Maximum Dielectric Withstanding Dc Voltage
500.0 volts at sea level
-
Operating Current Rating Per Function In Amps
3.0 6th radio interference
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Overall Height
1.209 inches minimum and 1.229 inches maximum
-
Full Load Minimum Insertion Loss At Specified Frequency In Decibels
50.0 and 10.0 and 20.0 and 20.0 and 3.0 and 50.0
-
Mounting Slot Width
0.123 inches minimum and 0.133 inches maximum
-
Load Impedance Per Function
50.0 ohms 4th radio interference
-
Maximum Voltage Drop Per Function
2.6 volts dc 1st radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 3rd radio interference
-
Maximum Voltage Drop Per Function
2.6 volts dc 2nd radio interference
-
Operating Voltage Rating And Type Per Function
260.0 volts dc 1st radio interference 1st function
-
Maximum Voltage Drop Per Function
2.6 volts dc 3rd radio interference