Technical Characteristics

  • Center To Center Distance Between Mounting Facilities Parallel To Width

    1.734 inches minimum single mounting facility single center group and 1.766 inches maximum single mounting facility single center group

  • Overall Width

    2.250 inches minimum and 2.375 inches maximum

  • Center To Center Distance Between Mounting Facilities Parallel To Length

    2.109 inches minimum single mounting facility single center group and 2.141 inches maximum single mounting facility single center group

  • Dummy Terminal Quantity (Non-Core)

    1

  • Specification/Standard Data

    81349-mil-t-27/328 government specification

  • Frequency Rating

    50.0 hertz minimum single component and 65.0 hertz maximum single component

  • Reliability Indicator

    not established

  • Thread Class (Non-Core)

    err-070

  • Input-Output Phase Relationship

    single phase to single phase single component

  • Winding Operating Voltage

    115.00 ac volts nominal single component single primary

  • Maximum Operating Temp

    130.0 deg celsius

  • Winding Shielding Method

    internal shield grounded to core single component

  • Inclosure Type

    hermetically sealed

  • Thread Series Designator

    unc single group

  • Overall Height

    3.936 inches minimum and 4.250 inches maximum

  • Terminal Type And Quantity

    6 wire hook

  • Unpackaged Unit Weight (Non-Core)

    3.300 pounds

  • Thread Direction (Non-Core)

    err-070

  • Mounting Facility Quantity

    4 single group

  • Overall Length

    2.625 inches minimum and 2.750 inches maximum

  • Winding Operating Voltage

    44.00 ac volts nominal single component all secondary

  • Maximum Transformer Power Rating

    30.0 volt-ampere single component

  • Winding Operating Current

    600.0 milliamperes ac nominal single component all secondary

  • Mounting Method

    threaded stud single group

  • Winding Function And Quantity

    1 primary single component and 2 secondary single component

  • Nominal Thread Size

    0.138 inches single group

  • ~1

    data on certain environmental and performance r

  • Test Data Document

    81349-mil-t-27 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...