BPF-L-070-100-10456

Filters and Networks

FILTER,BAND PASS

BPF-L-070-100-10456

5915-01-339-4139

5915 - Filters and Networks

Teledyne Wireless Llc

FILTER,BAND PASS

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Specified Frequencies Of Discrimination Per Function

    45.00 megahertz 2nd band pass and 68.00 megahertz 2nd band pass and 72.00 megahertz 2nd band pass and 72.00 megahertz 4th band pass and 72.00 megahertz 1st band pass and 45.00 megahertz 1st band pass and 45.00 megahertz 3rd band pass and 68.00 megahertz

  • Discrimination At Specified Frequencies Per Function In Decibels

    60.0 maximum 1st band pass

  • Specified Frequencies Of Discrimination Per Function

    95.00 megahertz 4th band pass

  • Overall Height

    0.430 inches nominal

  • Discrimination At Specified Frequencies Per Function In Decibels

    60.0 maximum 2nd band pass

  • Frequency Band Width Per Function

    72.00 megahertz 1st band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    60.0 maximum 3rd band pass

  • Frequency Band Width Per Function

    72.00 megahertz 2nd band pass

  • Load Impedance Per Function

    50.0 ohms 2nd band pass

  • Frequency Band Width Per Function

    72.00 megahertz 4th band pass

  • Body Width

    0.460 inches nominal

  • ~1

    3rd band pass and 68.00 megahertz 1st band pas

  • Voltage Standing Wave Ratio Per Function

    1.5 3rd band pass

  • Load Impedance Per Function

    50.0 ohms 4th band pass

  • Voltage Standing Wave Ratio Frequency Limits Per Function

    72.0 hercules no.5599.1 two phase to two phase

  • Functional Terminal Type And Quantity

    4 pin output 2nd function

  • Reference Frequency Per Function

    70.0 hercules no.5599.1 two phase to two phase

  • Source Impedance Rating Per Function

    50.0 ohms 2nd band pass

  • Body Height

    0.250 inches nominal

  • Body Material

    aluminum

  • Voltage Standing Wave Ratio Per Function

    1.5 4th band pass

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th band pass

  • Load Impedance Per Function

    50.0 ohms 1st band pass

  • Specified Frequencies Of Discrimination Per Function

    95.00 megahertz 2nd band pass

  • Features Provided

    moisture resistant and shock resistant

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st band pass

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.300 inches nominal

  • Body Length

    0.760 inches nominal

  • Precious Material And Location

    contact surfaces gold

  • Inclosure Type

    hermetically sealed

  • Specified Frequencies Of Discrimination Per Function

    95.00 megahertz 3rd band pass

  • Voltage Standing Wave Ratio Frequency Limits Per Function

    68.0 hercules no.5599.1 two phase to three phase and 68.0 hercules no.5599.1 two phase to two phase and 68.0 hercules no.5599.1 pulses per second and 68.0 hercules no.5599.1 hertz and 72.0 hercules no.5599.1 hertz

  • Mounting Facility Type And Quantity

    16 terminal

  • Source Impedance Rating Per Function

    50.0 ohms 3rd band pass

  • Frequency Band Width Per Function

    68.00 megahertz 2nd band pass and 68.00 megahertz 3rd band pass and 68.00 megahertz 4th band pass and 68.00 megahertz 1st band pass and 72.00 megahertz 3rd band pass

  • Source Impedance Rating Per Function

    50.0 ohms 4th band pass

  • Body Surface Treatment

    nickel

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd band pass

  • Operating Temp Range

    -55.0/+125.0 deg celsius

  • Discrimination At Specified Frequencies Per Function In Decibels

    1.0 minimum 3rd band pass and 1.0 minimum 1st band pass and 1.0 minimum 2nd band pass and 1.0 minimum 4th band pass and 60.0 maximum 4th band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    4.0 1st band pass

  • Voltage Standing Wave Ratio Per Function

    1.5 1st band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    4.0 2nd band pass

  • Reference Frequency Per Function

    70.0 hercules no.5599.1 hertz

  • Voltage Standing Wave Ratio Frequency Limits Per Function

    72.0 hercules no.5599.1 pulses per second

  • Source Impedance Rating Per Function

    50.0 ohms 1st band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    4.0 3rd band pass

  • Load Impedance Per Function

    50.0 ohms 3rd band pass

  • Reference Frequency Per Function

    70.0 hercules no.5599.1 pulses per second

  • Precious Material

    gold

  • Insertion Loss At Reference Frequency Per Function In Decibels

    4.0 4th band pass

  • Functional Terminal Type And Quantity

    4 pin input 1st function

  • Voltage Standing Wave Ratio Per Function

    1.5 2nd band pass

  • Style Designator

    rectangular terminal/terminals on one surface

  • Voltage Standing Wave Ratio Frequency Limits Per Function

    72.0 hercules no.5599.1 two phase to three phase

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd band pass

  • Special Features

    four filtered functions,four unfiltered function

  • Vibration Resistance Range In Hertz

    +10.0/+500.0

  • Reference Frequency Per Function

    70.0 hercules no.5599.1 two phase to three phase

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...