F55112
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
F55112
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Full Load Insertion Loss Frequencies In Megahertz
5.0 and 0.15 and 0.0 and 2.0 and 10.0 and 20.0
-
Body Height
2.250 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.620 inches nominal
-
Body Length
9.500 inches nominal
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.500 inches nominal
-
Full Load Minimum Insertion Loss At Specified Frequency In Decibels
50.0 and 50.0 and 60.0 and 70.0 and 70.0 and 70.0
-
Maximum Dielectric Withstanding Dc Voltage
2.25 kilovolts at sea level
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Features Provided
nut and washer
-
Power Line Frequency Rating Per Function In Hertz
400.0 1st radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference
-
Operating Current Rating Per Function In Amps
20.0 2nd radio interference
-
Operating Current Rating Per Function In Amps
20.0 3rd radio interference
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Body Surface Treatment
tin
-
Body Material
metal
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Body Width
5.500 inches nominal
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Maximum Voltage Drop Per Function
1.25 volts ac 1st radio interference
-
Special Features
three filtered functions
-
Functional Terminal Type And Quantity
3 threaded stud output 2nd function
-
Operating Voltage Rating And Type Per Function
125.0 volts ac 1st radio interference 1st function
-
Principal Circuitry Type Per Function
inductance-capacitance 3rd radio interference
-
Operating Voltage Rating And Type Per Function
125.0 volts ac 2nd radio interference 2nd function
-
Mounting Facility Screw Thread Series Designator
unc
-
Nominal Thread Size
0.164 inches
-
Functional Terminal Type And Quantity
2 threaded stud ground 3rd function
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Functional Terminal Type And Quantity
3 threaded stud input 1st function
-
Maximum Voltage Drop Per Function
1.25 volts ac 3rd radio interference
-
Maximum Voltage Drop Per Function
1.25 volts ac 2nd radio interference
-
Operating Current Rating Per Function In Amps
20.0 1st radio interference
-
Inclosure Type
hermetically sealed
-
Maximum Temp Rise
25.0 deg celsius
-
Power Line Frequency Rating Per Function In Hertz
400.0 2nd radio interference
-
Overall Length
11.000 inches nominal
-
Mounting Facility Type And Quantity
8 threaded stud
-
Power Line Frequency Rating Per Function In Hertz
400.0 3rd radio interference
-
Operating Voltage Rating And Type Per Function
125.0 volts ac 3rd radio interference 3rd function
-
Operating Temp Range
-55.0/+125.0 deg celsius