142608-0001
Coils and Transformers
COIL,ELECTRICAL
142608-0001
COIL,ELECTRICAL
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Hole Diameter
0.088 inches minimum single group
-
Winding Operating Current
1.5 amperes maximum of standard range b and better drop siding single component 2nd winding
-
Dc Resistance Rating In Ohms
0.010 single component 1st winding
-
Turn Quantity
24 single component 2nd winding
-
Terminal Type And Quantity
4 pin
-
Body Length
0.410 inches minimum and 0.420 inches maximum
-
Mounting Facility Quantity
1 single group
-
Maximum Operating Temp
130.0 deg celsius
-
Inductance Rating
15.00 microhenries nominal single component 1st winding
-
Winding Conductor Size
0.03196 inches american wire gage single component 1st winding
-
Reliability Indicator
not established
-
Winding Quantity
2 single component
-
Mounting Method
unthreaded hole single group
-
Dc Resistance Rating In Ohms
0.036 single component 2nd winding
-
Inclosure Type
fully inclosed
-
Winding Operating Voltage
50.00 ac pounds per hour wet single component all winding
-
Overall Diameter
0.793 inches maximum
-
Frequency Rating
10.0 kilohertz nominal single component
-
Rating Method
electrical single component all winding and winding turns single component all winding
-
Core Construction
s0lid single component
-
Turn Quantity
16 single component 1st winding
-
Winding Conductor Size
0.02010 inches american wire gage single component 2nd winding
-
Inductance Rating
32.00 microhenries nominal single component 2nd winding
-
Test Data Document
45413-142608 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Winding Operating Current
6.0 amperes maximum of standard range b and better drop siding single component 1st winding