3-401404
Coils and Transformers
TRANSFORMER,POWER
3-401404
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Quantity
4 single group
-
Overall Length
2.210 inches maximum
-
Winding Power Rating
102.0 volts-amperes single component single secondary
-
Overall Height
1.750 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Width
0.932 inches minimum single mounting facility single center group and 0.942 inches maximum single mounting facility single center group
-
Winding Operating Voltage
100.00 ac volts nominal single component single primary
-
Winding Operating Voltage
5.10 ac volts nominal single component single secondary
-
Mounting Method
threaded hole single group
-
Hazardous Locations/Environmental Protection
moisture resistant and flame resistant and vibration resistant
-
Inclosure Type
fully inclosed
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Unpackaged Unit Weight (Non-Core)
11.250 ounces
-
Reliability Indicator
not established
-
Frequency Rating
400.0 hertz nominal single component
-
Overall Width
1.870 inches maximum
-
Thread Class (Non-Core)
err-070
-
Input-Output Phase Relationship
single phase to single phase single component
-
Terminal Type And Quantity
4 tab, solder lug
-
Maximum Operating Temp
130.0 deg celsius
-
Thread Series Designator
unc single group
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.620 inches minimum single mounting facility single center group and 1.630 inches maximum single mounting facility single center group
-
Winding Operating Current
20.0 amperes ac nominal single component single secondary
-
Nominal Thread Size
0.138 inches single group