4200-004-20
Circuit Breakers
CIRCUIT BREAKER
4200-004-20
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Trip Release Method
magnetic single location
-
Switch Terminal Type
tab, solder lug
-
Bushing Length
0.250 inches nominal
-
Special Handling Feature
magnetic
-
Inclosure Protection Type For Which Designed
dustproof
-
Reset Method
manual
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 ac single location and 500.0 dc single location
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Mounting Surface To Terminal End Distance
1.525 inches maximum
-
Actuator Function
trip-reset
-
Thread Quantity Per Inch
32
-
Nominal Thread Size
0.438 inches
-
Circuit Protection Type
overcurrent single location
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Manual Actuator Type And Quantity
1 push-pull
-
Switch Contact Arrangement
single pole, double throw
-
Pole Quantity
1
-
~1
data on certain environmental and performance
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location
-
Internal Trip Release Configuration
series trip single location
-
Operating Voltage Type And Rating Per Pole In Volts
200.0 ac single location and 28.0 dc single location
-
Trip Release Characteristic
time delay single location
-
Switch Voltage Rating And Type In Volts
200.0 ac and 28.0 dc
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Specification/Standard Data
96906-ms26574 government standard
-
Frequency In Hertz
400.0 single location
-
Body Style
single pole type
-
Body Length
0.780 inches maximum
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac single location and 20.0 amperes dc single location
-
Terminal Type And Quantity
2 tab w/screw
-
Auxiliary Switch Function And Quantity
1 alarm
-
Switch Current Rating And Type In Amps
3.0 ac and 5.0 dc
-
Thread Series Designator
un
-
Body Width
0.593 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
0.593 inches nominal
-
Switch Location And Position Designation
internal at pole one
-
Case Material
plastic
-
Test Data Document
81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type