AP14-24050-1
Circuit Breakers
CIRCUIT BREAKER
AP14-24050-1
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Terminal Type And Quantity
6 wire hook
-
Thread Series Designator
unef
-
Inclosure Protection Type For Which Designed
hermetically sealed
-
Trip Delay Time In Seconds Per Rated Continuous Current
7.500 maximum at 200 pct all locations
-
Nominal Thread Size
0.375 inches
-
Internal Trip Release Configuration
series/relay trip second location
-
Trip Release Characteristic
time delay all locations
-
Trip Release Method
magnetic all locations
-
Circuit Protection Type
overcurrent all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 dc all locations
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc all locations
-
Iii Storage Type
general purpose warehouse
-
Iii Arc Quenching Method
magnetic blowout
-
Mounting Surface To Terminal End Distance
1.780 inches maximum
-
Iii Fragility Factor
moderately rugged
-
Iii Nonturn Device Diameter
0.140 inches nominal
-
Iii Nonturn Device Radius
0.625 inches nominal
-
Iii Nonturn Device Location
at 3 oclock and
-
Center To Center Distance Between Terminals Parallel To Width
0.625 inches nominal
-
Case Material
metal
-
Body Length
1.500 inches maximum
-
Frequency In Hertz
400.0 all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
1.000 minimum at 200 pct and
-
Trip Release Duty Cycle
continuous second location
-
Actuator Function
trip-reset
-
Auxiliary Trip Coil Voltage Type And Rating In Volts
24.0 dc nominal second location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac and
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac and
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes dc all locations
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac and
-
Thread Quantity Per Inch
32
-
Iii Special Handling Feature
magnetic
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Pole Quantity
2
-
Iii Nonturn Device Length
0.130 inches nominal
-
Iii Nonturn Device Location
at 9 oclock
-
Center To Center Distance Between Terminals Parallel To Length
0.875 inches nominal
-
Body Width
1.250 inches maximum
-
Bushing Length
0.380 inches maximum
-
Body Style
1b multipole-single actuator type
-
Internal Trip Release Configuration
series trip first location
-
Actuator Position Designation
between pole one and two
-
Manual Actuator Type And Quantity
1 toggle
-
Main Contact Tripping Mechanism Type
trip free
-
Reset Method
manual
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations