AP14-24050-1

Circuit Breakers

CIRCUIT BREAKER

AP14-24050-1

5925-01-342-3113

5925 - Circuit Breakers

Miltope Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    6 wire hook

  • Thread Series Designator

    unef

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Trip Delay Time In Seconds Per Rated Continuous Current

    7.500 maximum at 200 pct all locations

  • Nominal Thread Size

    0.375 inches

  • Internal Trip Release Configuration

    series/relay trip second location

  • Trip Release Characteristic

    time delay all locations

  • Trip Release Method

    magnetic all locations

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc all locations

  • Iii Storage Type

    general purpose warehouse

  • Iii Arc Quenching Method

    magnetic blowout

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Iii Fragility Factor

    moderately rugged

  • Iii Nonturn Device Diameter

    0.140 inches nominal

  • Iii Nonturn Device Radius

    0.625 inches nominal

  • Iii Nonturn Device Location

    at 3 oclock and

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Case Material

    metal

  • Body Length

    1.500 inches maximum

  • Frequency In Hertz

    400.0 all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.000 minimum at 200 pct and

  • Trip Release Duty Cycle

    continuous second location

  • Actuator Function

    trip-reset

  • Auxiliary Trip Coil Voltage Type And Rating In Volts

    24.0 dc nominal second location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac and

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac and

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes dc all locations

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac and

  • Thread Quantity Per Inch

    32

  • Iii Special Handling Feature

    magnetic

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Pole Quantity

    2

  • Iii Nonturn Device Length

    0.130 inches nominal

  • Iii Nonturn Device Location

    at 9 oclock

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Body Width

    1.250 inches maximum

  • Bushing Length

    0.380 inches maximum

  • Body Style

    1b multipole-single actuator type

  • Internal Trip Release Configuration

    series trip first location

  • Actuator Position Designation

    between pole one and two

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...