MIL-C-5809
Circuit Breakers
CIRCUIT BREAKER
MIL-C-5809
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Special Handling Feature
magnetic
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Thread Series Designator
unc
-
Reset Method
manual
-
Center To Center Distance Between Terminals Parallel To Width
1.500 inches nominal
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Manual Actuator Type And Quantity
1 push button
-
Mounting Surface To Terminal End Distance
2.370 inches nominal
-
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 minimum at 200 pct all locations and 70.000 maximum at 200 pct all locations
-
Thread Quantity Per Inch
32
-
Body Style
multipole-multiple actuator type
-
Trip Release Method
thermal-magnetic all locations
-
Inclosure Protection Type For Which Designed
humidity resistant and shock resistant and corrosion resistant and hermetically sealed
-
Actuator Position Designation
at pole two
-
Mounting Facility Type And Quantity
6 threaded hole
-
Trip Release Ambient Temp Rating
77.0 deg fahrenheit nominal all locations
-
Case Material
metal
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac all locations
-
Nominal Thread Size
0.138 inches
-
Center To Center Distance Between Terminals Parallel To Length
1.190 inches nominal
-
Main Contact Tripping Mechanism Type
trip free
-
Body Length
2.200 inches maximum
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 all locations
-
Bushing Length
0.235 inches minimum and 0.250 inches maximum
-
Body Width
2.270 inches maximum
-
Frequency In Hertz
400.0 all locations
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac all locations
-
Terminal Type And Quantity
6 tab w/screw
-
Unpackaged Unit Weight
0.650 pounds