6752-330-35

Circuit Breakers

CIRCUIT BREAKER

6752-330-35

5925-01-344-8261

5925 - Circuit Breakers

Peerless Electronics Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Unpackaged Unit Weight

    0.650 pounds

  • Bushing Length

    0.318 inches nominal

  • Inclosure Protection Type For Which Designed

    corrosion resistant and shock resistant and humidity resistant and hermetically sealed

  • Terminal Type And Quantity

    6 tab w/screw

  • Body Height

    2.370 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    140.0 all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac all locations

  • Frequency In Hertz

    400.0 all locations

  • Body Width

    2.270 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Body Length

    2.200 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Center To Center Distance Between Terminals Parallel To Length

    1.190 inches nominal

  • Nominal Thread Size

    0.138 inches

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Case Material

    metal

  • Maximum Continuous Load Current Rating Per Pole

    35.0 amperes ac all locations

  • Body Style

    multipole-single actuator type

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.800 inches minimum and 1.820 inches maximum

  • Actuator Position Designation

    at pole two

  • Manual Actuator Type And Quantity

    1 push-pull

  • Trip Release Method

    thermal-magnetic all locations

  • Thread Quantity Per Inch

    32

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct all locations and 70.000 maximum at 200 pct all locations

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Reset Method

    manual

  • Thread Series Designator

    unc

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Special Handling Feature

    magnetic

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...