MIL-PRF-6106
Relays and Solenoids
RELAY,ELECTROMAGNETIC
MIL-PRF-6106
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Test Data Document
81349-mil-r-6106 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Fragility Factor
moderately rugged
-
Main Contact Load Current Rating At Maximum Rated Voltage
15.0 amperes ac lamp load and 10.0 amperes dc lamp load
-
~1
data on certain environmental and performance
-
Mounting Facility Type And Quantity
4 unthreaded hole single mounting facility
-
Mounting Facility Pattern
rectangular single mounting facility
-
Storage Type
general purpose warehouse
-
Auxiliary Contact Load Current Rating At Maximum Rated Voltage
3.0 probe ac resistive load and 3.0 probe dc resistive load
-
Main Contact Load Current Rating At Maximum Rated Voltage
60.0 amperes ac resistive load and 50.0 amperes dc resistive load
-
Unthreaded Mounting Hole Diameter
0.168 inches minimum single mounting facility and 0.175 inches maximum single mounting facility
-
Environmental Protection
hermetic
-
Auxiliary Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Auxiliary Contact Load Current Rating At Maximum Rated Voltage
1.0 probe ac lamp load and 1.0 probe dc lamp load
-
Main Contact Load Current Rating At Maximum Rated Voltage
40.0 amperes ac motor load and 20.0 amperes dc motor load
-
Arc Quenching Method
air
-
Overall Height
3.130 inches maximum
-
Terminal Type And Quantity
13 threaded stud all functions
-
Thread Quantity Per Inch
32 single mounting facility
-
Winding Quantity
1
-
Thread Class
2a single mounting facility
-
Overall Length
2.500 inches maximum
-
Thread Series Designator
unf single mounting facility
-
Cubic Measure
0.707 cubic inches
-
Thread Direction
right-hand single mounting facility
-
Coil Quantity
1
-
Nonpile-Up Auxiliary Contact Arrangement
1 pole, single throw, normally closed, momentary action
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.990 inches minimum single mounting facility and 2.010 inches maximum single mounting facility
-
Main Contact Load Current Rating At Maximum Rated Voltage
20.0 amperes dc inductive load
-
Overall Width
2.440 inches maximum
-
Nonpile-Up Main Contact Arrangement
3 pole, double throw, one position momentary
-
Nominal Thread Size
0.190 inches single mounting facility
-
Specification/Standard Data
96906-ms27751 government standard
-
Winding Dc Resistance Rating
200.0 ohms nominal single winding
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.990 inches minimum single mounting facility and 2.010 inches maximum single mounting facility
-
Duty Type
continuous
-
Nominal Operating Current Rating And Type
160.0 milliamperes dc single winding
-
Auxiliary Contact Load Current Rating At Maximum Rated Voltage
3.0 probe ac inductive load and 3.0 probe dc inductive load
-
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Purpose For Which Designed
general
-
Operating Voltage Rating And Type At Specified Temp
28.0 volts dc 25 deg celsius single winding