Technical Characteristics
-
Mounting Facility Quantity
4 single group
-
Winding Operating Voltage
13.47 ac volts nominal single component 4th secondary
-
Winding Operating Voltage
23.66 ac volts nominal single component 1st secondary
-
Maximum Operating Temp
170.0 deg celsius
-
Winding Tap Location (Non-Core)
err-070
-
Overall Height
1.375 inches maximum
-
Inclosure Type
fully inclosed
-
Terminal Type And Quantity
21 wire lead
-
Winding Function And Quantity
1 primary single component and 4 secondary single component
-
Mounting Method
unthreaded hole single group
-
Specification/Standard Data
19059-700799 manufacturers source control
-
Winding Shielding Method
internal shield brought out to terminal single component
-
Overall Length
3.720 inches maximum
-
Reliability Indicator
not established
-
Frequency Rating
400.0 hertz nominal single component
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.625 inches nominal single mounting facility single center group
-
Mounting Hole Diameter
0.140 inches nominal single group
-
Input-Output Phase Relationship
single phase to single phase single component
-
Winding Operating Voltage
115.00 ac volts nominal single component single primary
-
Overall Width
2.500 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.125 inches nominal single mounting facility single center group
-
Winding Operating Voltage
11.14 ac volts nominal single component 3rd secondary
-
Winding Operating Voltage
2.316 ac kilovolts nominal single component 2nd secondary