47A530118P19
Circuit Breakers
CIRCUIT BREAKER
47A530118P19
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Internal Trip Release Configuration
relay trip fourth location
-
Fragility Factor
moderately rugged
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac third location
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Internal Trip Release Configuration
series trip second location
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac first location
-
Body Width
3.000 inches nominal
-
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac fourth location
-
Nominal Thread Size
0.138 inches
-
Trip Release Characteristic
time delay second location
-
Internal Trip Release Configuration
series trip third location
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac second location
-
Mounting Surface To Terminal End Distance
2.471 inches nominal
-
Inclosure Protection Type For Which Designed
dustproof and fungus proof
-
Main Contact Tripping Mechanism Type
trip free
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
-
Arc Quenching Method
magnetic blowout
-
Trip Release Characteristic
time delay third location
-
Body Length
2.500 inches nominal
-
Boss Height
0.140 inches nominal
-
Trip Release Characteristic
instantaneous fourth location
-
Frequency In Hertz
50.0 all locations or 60.0 all locations
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Center To Center Distance Between Terminals Parallel To Length
1.936 inches nominal
-
Manual Actuator Type And Quantity
4 toggle
-
Case Material
plastic
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches nominal
-
Pole Quantity
4
-
External Actuator Linkage Arrangement
one, two, three, and four linked
-
Special Handling Feature
magnetic
-
Circuit Protection Type
overcurrent all locations
-
Terminal Type And Quantity
10 threaded stud
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 minimum at 200 pct second location and 3.000 minimum at 200 pct third location and 3.000 minimum at 200 pct first location and 20.000 maximum at 200 pct third location
-
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 maximum at 200 pct first location
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 maximum at 200 pct second location
-
Mounting Facility Type And Quantity
8 threaded hole
-
Trip Release Method
magnetic all locations
-
Body Style
multipole-multiple actuator type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Internal Trip Release Configuration
series trip first location
-
Trip Release Characteristic
time delay first location