TF58-011-02
Coils and Transformers
TRANSFORMER,POWER
TF58-011-02
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Operating Current
5.0 milliamperes ac nominal single component single secondary
-
Input-Output Phase Relationship
single phase to single phase single component
-
Mounting Method
terminal single group
-
Reliability Indicator
not established
-
Terminal Type And Quantity
2 wire lead
-
Winding Operating Voltage
1.00 ac volts nominal single component single primary
-
Overall Diameter
0.760 inches maximum
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Winding Operating Voltage
1.00 ac volts nominal single component single secondary
-
Inclosure Type
fully inclosed
-
Maximum Operating Temp
155.0 deg celsius
-
Winding Operating Current
7.0 milliamperes ac nominal single component single primary
-
Special Features
dash 01 has flex leads for terminals; dash o2 has solid leads for terminalsi
-
Body Length
0.460 inches maximum
-
Test Data Document
08748-tf58-011 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Frequency Rating
80.0 kilohertz nominal single component
-
Maximum Transformer Power Rating
0.1 volt-ampere single component