W68X2Q5-2-20
Circuit Breakers
CIRCUIT BREAKER
W68X2Q5-2-20
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Circuit Protection Type
overcurrent all locations
-
Pole Quantity
2
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.660 inches nominal
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes dc all locations
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Body Length
2.000 inches nominal
-
Internal Trip Release Configuration
series trip all locations
-
Mounting Facility Type And Quantity
4 threaded hole
-
Mounting Surface To Terminal End Distance
2.032 inches maximum
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 dc all locations
-
Trip Release Method
magnetic all locations
-
Body Style
multipole-multiple actuator type
-
Trip Delay Time In Seconds Per Rated Continuous Current
1.000 minimum at 200 pct all locations and 10.000 maximum at 200 pct all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Operating Voltage Type And Rating Per Pole In Volts
65.0 dc all locations
-
Nominal Thread Size
0.138 inches
-
Main Contact Tripping Mechanism Type
trip free
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
-
Terminal Type And Quantity
4 tab, solder lug
-
Manual Actuator Type And Quantity
2 toggle
-
Body Width
1.515 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
1.812 inches nominal
-
External Actuator Linkage Arrangement
one and two linked
-
Case Material
plastic
-
Boss Height
0.130 inches nominal