T2460
Coils and Transformers
TRANSFORMER,POWER
T2460
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Thread Class
2b single group
-
Body Length
0.760 inches maximum
-
Body Width
0.760 inches maximum
-
Mounting Facility Quantity
1 single group
-
Winding Function And Quantity
1 primary and 1 secondary single component
-
Winding Operating Current
2.0 milliamperes ac maximum single component single secondary
-
Terminal Type And Quantity
4 turret
-
Thread Series Designator
unc single group
-
Unpackaged Unit Weight
25.0 grams
-
Winding Operating Voltage
26.00 ac volts nominal single component single secondary
-
Winding Operating Voltage
26.00 ac volts nominal single component single primary
-
Nominal Thread Size
0.086 inches single group
-
Cubic Measure
0.4 cubic inches
-
Mounting Method
threaded hole single group
-
Inclosure Type
fully inclosed
-
Input-Output Phase Relationship
single phase to single phase single component
-
Frequency Rating
400.0 hertz nominal single component
-
Overall Height
0.750 inches maximum
-
Reliability Indicator
not established
-
Thread Direction
right-hand single group