203-2-1-62F-103-4-1-1 2/3
Circuit Breakers
CIRCUIT BREAKER
203-2-1-62F-103-4-1-1 2/3
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Type And Quantity
2 clip
-
Trip Release Method
magnetic single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location
-
Reset Method
manual
-
Actuator Position Designation
at pole one
-
Actuator Function
trip-reset
-
Body Length
2.000 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.610 inches nominal
-
Circuit Protection Type
overcurrent single location
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location
-
Pole Quantity
1
-
Manual Actuator Type And Quantity
1 toggle
-
Internal Trip Release Configuration
series trip single location
-
Mounting Surface To Terminal End Distance
1.770 inches maximum
-
Trip Release Characteristic
time delay single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Main Contact Tripping Mechanism Type
trip free
-
Boss Height
0.125 inches nominal
-
Terminal Type And Quantity
2 quick disconnect, male
-
Body Style
single pole type
-
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac single location
-
Center To Center Distance Between Terminals Parallel To Length
1.250 inches nominal
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.500 minimum at 200 pct single location and 9.000 maximum at 200 pct single location
-
Body Width
0.920 inches nominal
-
Case Material
plastic
-
Frequency In Hertz
50.0 single location or 60.0 single location